4
5
6
3
2
14
Valid for contact arrangement:
03a, 04a, 05a, 06a, 07a
13,6
12
12
Panel cutout M 1:1
T 3627 150 U
T 3627 159 U
T 3527 150 U
T 3527 159 U
7
T 3447 150 U
(07-b)
T 3447 159 U
(12-a)
18 0
max 3,5
8
+0,1
19,1 0
M18x0,75
E
20
M18x0,75
(08-a)
E
7
2,8
6,6
(07-a)
+0,1
6
(06-a)
1
shown with ring nut
5
(05-b)
D
Rated voltage
Rated voltage
Rated impulse
withstand voltage
Pollution degree
Installation category
Insulation group
C
Current rating
Insulation resistance
Contact resistance
Climatic category
Temperatur range
IP degree
Insertion and
withdrawal force
B
Mechanical operation
DIN
Standard
EN 61076-2-106
IEC 60130-9
1)
IEC
60664-1
UL 1977
IEC
60664-1
60664-1
IEC 60664-1
IEC 60664-1
IEC 60512-5-2
UL 1977
IEC 60512-3-1
IEC 60512-2-1
IEC 60668-1
IEC 60668-1
IEC 60529
IEC
IEC
IEC
60512-13-2
60512-9-1
Housing material
Dielectric material
Contacts
Termination technique
4
04-a
5
5S
6
7
05-a 05-b 06-a 07-a
300 V
300 V 100 V
300 V
(100 V)
(63 V) (32 V)
(63 V)
250 V
1500 V
1200 V
1500 V
(840 V)
(500 V)
(840 V)
1 (2)
7
8
12
14
07-b
08-a
12-a
14-a
5
100
V
150
(32 V)
10A/+40°C
1200 V
3A/+40°C/+104°F
Contact
Number
arrangement
of
View on
contacts
mating side
2)
40 / 100 / 56
35N
50N
55N
60N
silver >500 mating cycles
gold >1000 mating cycles
brass or zinc die cast nickel plated or thermoplast
thermoplastic
silver or gold plated, please order contacts separately acc. to drawing
M-N 02 015 00XX X (3-8pol) or M-N 02 010 0157 X U (12-14pol)
C
type-number-crimp
with hex nut SW20
0,09-0,25mm² /
28-24 AWG
locking system
bayonet locking outside (mateable with locking inside)
dimension of nut
23
Gewicht (errechnet) / Calc WT :
Prüfmaß / Testdimension
Teileindex / Partindexnumber:
Zul. Abw./Tolerances :
ISO
Bagatelle change:
2768-c
Maßstab / Scale : 2:1;1:1
CUSTOMER DRAWING
DIN / ISO
13715
28.04.2020
Drawn MCARLE
Status Released
Gepr. 30.04.2020
Checked MGRIMM
A3
Gez.
1)
Edition 2000-05
under operating conditions >108 Ohm
All technical data have been measured in a laboratory environment and can be different during pratical usage of the product. Any product
informtion is for descriptive usage only and not legally binding; particulary the information does not constitute or provide any legal guaranties.
Do not connect or disconnect under load. Metal housing parts shall be securely incoporated to protected ground.
Parts according to directive 2002/95/EG (RoHS).
2)
6
T 3277 159 U
50N
UL 94 VO
7
T 3277 150 U
type-number-crimp
with ring nut
IP 40
Flamability
8
T 3327 159 U
-40°C...+100°C / -40°F...+212°F
30N
D
4
T 3327 150 U
(04-a)
(03-a)
10 Ohm
T 3427 159 U
V
(32 V)
60 V
I
II,
T 3427 150 U
T 3377 150 U
(05-a)
-
crimp
2-6 pol (exclusive 5S): 0,09-1,0mm² / 28-18 AWG
5S, 7, 7S, 8pol: 0,09-0,75mm² / 28-20 AWG
Wire gauge
A
3
03-a
T 3437 159 U
20
Number of contacts
Contact arrangement
Contact arrangement
T 3437 150 U
0
6,6
1
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung
und Mitteilung ihres Inhalts nicht gestattet, soweit nicht
ausdrücklich zugestanden. Zuwiderhandlungen verpflichten
zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung
oder Gebrauchsmuster-Eintragung vorbehalten.
F
12
+0,1
6,4
T 3647 159 U
FAI2020-001468
13,6
T 3647 150 U
5
202000001
Index Änderung/Description
01
30.04.2020 MCARL
Datum/Date Name
Gerätedose
female receptacle
Amphenol Tuchel
Industrial GmbH M
Blatt/Sheet
NB T 3XX7 15X U
Ers. f. / Replacement for : M-NB T 3XX7 150 Rev01
1
1
Bl.
NXM-V01
Valid for contact arrangement:
05b, 07b, 08a, 12a, 14a
F
20
Copying of this document and giving it to others and the use
or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of
damages. All rights are reserved in the event of the grant of
a patent or the registration of the utility model or design.
(14-a)
1
SW20
7
8
很抱歉,暂时无法提供与“T 3377 150”相匹配的价格&库存,您可以联系我们找货